CDCP CERTIFICATION BOOK TORRENT & LATEST CDCP DUMPS FILES

CDCP Certification Book Torrent & Latest CDCP Dumps Files

CDCP Certification Book Torrent & Latest CDCP Dumps Files

Blog Article

Tags: CDCP Certification Book Torrent, Latest CDCP Dumps Files, Training CDCP Tools, CDCP Download Pdf, CDCP Reliable Exam Testking

Applying the international recognition third party for payment for CDCP exam cram, and if you choose us, your money and account safety can be guaranteed. And the third party will protect the interests of you. In addition, CDCP learning materials are edited and verified by professional experts who possess the professional knowledge for the exam, and the quality can be guaranteed. We are pass guarantee and money back guarantee and if you fail to pass the exam, we will give you full refund. We provide free update for 365 days for CDCP Exam Materials for you, so that you can know the latest information for the exam, and the update version will be sent to your email automatically.

EXIN CDCP Exam Syllabus Topics:

TopicDetails
Topic 1
  • Physical Security and Safety: Sub-topics are about physical security considerations and physical safety considerations.
Topic 2
  • Power Infrastructure: It focuses ATS and STS systems, redundancy levels and techniques, static and dynamic UPS systems, battery types, thermo-graphics, and renewable energy factor (REF).
Topic 3
  • Fire Safety
  • Protection: This topic gives an understanding of standards for fire suppression, detection systems, total flooding fire suppression techniques, and handheld extinguishers. Additionally, it covers Signage and safety.
Topic 4
  • Raised Floor
  • Suspended Ceiling: The topic discusses applicable standards, signal reference grid, and disability act and regulations.
Topic 5
  • Data Centre Location, Building and Construction: It focuses on appropriate sites and components of an effective data centre and supporting facilities setup.
Topic 6
  • Cooling Infrastructure: The topic focuses on liquid immersion cooling, supplemental cooling options, sensible and latent heat definitions, and temperature and humidity recommendations.
Topic 7
  • Electro Magnetic Fields: The topic deals with effects of EMF on human health and equipment (H)EMP, standards, and EMF shielding solutions.
Topic 8
  • Equipment Racks: It discusses power rail
  • strip options, security considerations, and rack standards, properties and selection criteria.

>> CDCP Certification Book Torrent <<

Latest CDCP Dumps Files | Training CDCP Tools

TrainingDumps has been designing and offering real EXIN Certified Data Centre Professional (CDCP) exam dumps for many years. We regularly update our valid EXIN CDCP certification test preparation material to keep them in line with the current Certified Data Centre Professional (CDCP) (CDCP) exam content and industry standards. Professionals from different countries give us their valuable feedback to refine CDCP actual dumps even more.

EXIN Certified Data Centre Professional (CDCP) Sample Questions (Q24-Q29):

NEW QUESTION # 24
Starting from which Rating does the requirement of Concurrently Maintainability becomes relevant?

  • A. Rated-3
  • B. Rated-4
  • C. Rated-1
  • D. Rated-2

Answer: A

Explanation:
The requirement of Concurrently Maintainability becomes relevant starting from Rated-3, according to the Uptime Institute Tier Classification System1. Concurrently Maintainability means that any component or system in the data centre can be maintained or replaced without affecting the availability of the IT equipment.
This requires having redundant capacity components and multiple independent distribution paths serving the IT equipment. Rated-3 data centres are designed to achieve Concurrently Maintainability and have a minimum uptime of 99.982%. Rated-4 data centres also have Concurrently Maintainability, but they also have Fault Tolerance, which means that they can withstand any single unplanned event without affecting the availability of the IT equipment. Rated-4 data centres have a minimum uptime of 99.995%. Rated-1 and Rated-2 data centres do not have Concurrently Maintainability, as they have only one distribution path serving the IT equipment and no redundant capacity components. Rated-1 data centres have a minimum uptime of 99.671% and Rated-2 data centres have a minimum uptime of 99.741%.
References:
1: Uptime Institute Tier Classification System2, page 1, section 1 2: Data Center Tiers Classification Explained: (Tier 1, 2, 3, 4)3, page 1, section 1 3: Data Center Tier Standards4, page 1, section 1


NEW QUESTION # 25
A fire extinguisher in the data centre is found which is classed as ABC.
Is this suitable?

  • A. Depends on the brand
  • B. Only for fires not related to electrical power
  • C. No
  • D. Yes

Answer: C

Explanation:
A fire extinguisher in the data centre that is classed as ABC is not suitable, because it contains dry chemical powder that can damage the ICT equipment and the data. ABC fire extinguishers are designed to fight Class A, B, and C fires, which are fueled by combustible materials, flammable liquids or gases, and electrical equipment, respectively. However, the dry chemical powder can leave a corrosive residue on the ICT equipment, which can cause short circuits, data loss, or malfunction. Moreover, the dry chemical powder can be difficult to clean, especially from the small spaces and crevices of the ICT equipment. Therefore, ABC fire extinguishers are not recommended for data centres, and should be replaced with more suitable fire extinguishers, such as clean agent fire extinguishers, which use gas or liquid that does not leave any residue or harm the ICT equipment.
References:
1: CDCP Preparation Guide, page 24, section 2.4.3 2: Data Center Fire Suppression: Overview & Protection Guide3, page 1, section 1 4: Fire Extinguisher Classes and Suitability5, page 1, section 1 6: SAFETY DATA SHEET Commercial ABC Dry Chemical (Fire Extinguishing Agent ...7, page 1,


NEW QUESTION # 26
What is the best practice for cutting holes in the raised floor tile?

  • A. Draw a line in the middle of the tile and never touch the line when making the cut.
  • B. Draw a cross on the tile and when making a cut-out do not touch a line and avoid the corners.
  • C. Anywhere as data centre tiles are designed to allow cut-outs anywhere.
  • D. Cut the tiles at the corner so the pedestals can be used as a vertical cable manager.

Answer: B

Explanation:
According to the Raised Floor Installation Manual, the best practice for cutting holes in the raised floor tile is to draw a cross on the tile and when making a cut-out do not touch a line and avoid the corners1. This ensures that the structural integrity and load-bearing capacity of the tile are not compromised. Cutting holes anywhere, touching the line, or cutting the corners can weaken the tile and cause it to crack or collapse1. Additionally, the manual recommends using a drill press or a reciprocating saw with a metal or bi-metal cutting blade, and deburring all sharp edges1.
References: 1: Raised Floor Installation Manual, E. Recommended Cutting Tools, Page 1


NEW QUESTION # 27
The UPS vendor is offering the latest model of their UPS to you. The vendor indicates that the UPS is categorized as VFD class.
Is this UPS a fit for your mission-critical data centre?

  • A. Yes, but only if you oversize the battery bank with 10%.
  • B. No
  • C. Yes
  • D. Yes, but only if they install it with a 12-pulse rectifier.

Answer: B

Explanation:
A UPS (uninterruptible power supply) that is categorized as VFD class is not a fit for your mission-critical data centre, because it does not provide adequate protection against voltage and frequency variations. VFD stands for Voltage and Frequency Dependent, which means that the output voltage and frequency of the UPS depend on the input voltage and frequency. VFD UPSs are also known as offline, standby, or line-interactive UPSs. They typically switch to battery power only when the input power fails or goes beyond a certain threshold. However, this switching may cause a brief interruption or a transient in the output power, which can affect the performance and reliability of the ICT equipment. Moreover, VFD UPSs do not filter or regulate the input power, which means that they pass on any voltage or frequency fluctuations, harmonics, or noise to the output power. These power quality issues can also damage or degrade the ICT equipment and the data.
For your mission-critical data centre, you need a UPS that is categorized as VFI class, which stands for Voltage and Frequency Independent. VFI UPSs are also known as online, continuous, or double-conversion UPSs. They provide a constant and clean output power that is independent of the input power. VFI UPSs convert the input AC power to DC power, and then convert it back to AC power with the desired voltage and frequency. This double conversion process isolates the output power from the input power, and eliminates any power quality issues. VFI UPSs also have zero switching time, which means that they do not cause any interruption or transient in the output power when switching to battery power. VFI UPSs are designed to protect the ICT equipment and the data from any adverse effects of voltage and frequency variations, and to ensure the highest level of availability and reliability.
References:
1: CDCP Preparation Guide, page 17, section 2.3.1 2: Understanding UPS Classification: Fuji Electric's Technical Guide3, page 1, section 1 4: Uninterruptible Power Supplies Key Product Criteria5, page 1, section
1 6: UPS Function: Reduced Input Voltage for VFDs - KEB7, page 1, section 1


NEW QUESTION # 28
What is the minimum clearance space required below water sprinkler heads and nozzles of gas-based fire suppression systems?

  • A. 120 cm / 47 inches
  • B. 64 cm / 25 inches
  • C. 46 cm / 18 inches
  • D. 60 cm / 24 inches

Answer: C

Explanation:
The minimum clearance space required below water sprinkler heads and nozzles of gas-based fire suppression systems is 46 cm / 18 inches, according to the CDCP Preparation Guide1 and OSHA regulation 29 CFR
1910.159 © (10)2. This clearance space is necessary to ensure that the sprinkler spray or gas discharge can reach the fire and cover the protected area effectively. Any material or obstruction below this clearance space can interfere with the sprinkler or gas distribution and reduce the fire suppression performance. Therefore, building owners and managers should ensure that all storage and objects in the data centre are kept below this clearance space, and that the clearance space is maintained at all times.
References:
1: CDCP Preparation Guide, page 24, section 2.4.3 2: Clarification of OSHA regulation 29 CFR
1910.159©(10), Sprinkler ...3, page 1, section 1


NEW QUESTION # 29
......

A Certified Data Centre Professional (CDCP) (CDCP) practice questions is a helpful, proven strategy to crack the Certified Data Centre Professional (CDCP) (CDCP) exam successfully. It helps candidates to know their weaknesses and overall performance. TrainingDumps software has hundreds of Certified Data Centre Professional (CDCP) (CDCP) exam dumps that are useful to practice in real-time. The Certified Data Centre Professional (CDCP) (CDCP) practice questions have a close resemblance with the actual Certified Data Centre Professional (CDCP) (CDCP) exam.

Latest CDCP Dumps Files: https://www.trainingdumps.com/CDCP_exam-valid-dumps.html